  • CAN Bus Layout Quick-Reference Values
  • Introduction
  • From CAN Node Schematic to PCB Layout
  • Component Placement and Signal Flow of CAN Bus PCB
  • Differential Pair Routing and CAN Bus Layout Impedance
  • Termination Design on the PCB
  • Grounding and EMC in CAN Bus Design
  • CAN Bus PCB Layout Checklist
  • FAQs about CAN Bus PCB Layout
  • Conclusion about CAN Bus PCB Layout

Key Takeaways

  • Route CANH and CANL as a 120 Ω differential pair, and solve trace width and spacing from your actual stackup.
  • Follow the signal-path placement order: bus connectors, 120 Ω termination, transceiver, CAN controller. Reserve footprints for TVS/ESD diodes and a common-mode choke if the environment is noisy.
  • Terminate only the two physical end nodes, and switch the 120 Ω resistor in or out with a jumper so one board works at the end or in the middle of the bus.
  • Keep on-board stubs effectively zero, and hold the pair length-matched with constant spacing.
  • Never route the pair across a plane split. An unbroken ground plane is the cheapest EMC fix.

CAN Bus Layout Quick-Reference Values

These are the numbers most CAN layout reviews check first.

ParameterValue
Differential impedance120 Ω (ISO 11898-2)
Termination120 Ω at the two physical end nodes only, switched by a jumper
Split termination (optional alternative)2 × 60 Ω in series, about 4.7 nF from midpoint to GND
Stub limit, classic CAN< about 0.3 m at 1 Mbps
Stub limit, CAN FDShorter than classic CAN; no fixed standard figure, keep as short as possible
Rather Not Risk a CAN Bus Re-Spin?

Upload your schematic; our layout engineers will route the 120 Ω CANH/CANL pair and hand back a board that is ready to manufacture.

Start My Layout — US$90 Off

Introduction

A CAN node that runs flawlessly on the bench can start throwing intermittent bus errors, or fail EMC testing, the moment it is cabled into a vehicle or a factory line. Teams often blame the transceiver, but the cause is usually physical, and following sound CAN bus PCB layout guidelines is what avoids the re-spin. CAN is a differential bus (CANH and CANL) defined by ISO 11898 and built to survive the noisy conditions of automotive and industrial environments.

That noise immunity only survives if the board protects it. A transceiver cannot fix uneven wires, a missing ground plane, or a resistor in the wrong place. The layout decides how tough the bus is, long before any cable is plugged in.

This guide connects the node schematic to the board. The reference node is an MCP2515 CAN controller with a TJA1050 transceiver, one 120 Ω termination resistor (R2) selected by a jumper (H1), and two CANH/CANL bus connectors (H2 and H3). The guide then covers placement order, impedance and trace width, termination, and grounding. Every recommendation is aimed at one goal: a CAN bus PCB that works the same way in the field as it did on the bench.

From CAN Node Schematic to PCB Layout

Figure 1. CAN node schematic.

Figure 1. CAN node schematic.

Every robust CAN layout starts with knowing what each element in the node schematic does physically. On paper, each block is just a symbol. On the board, it becomes a position, a current path, and a length rule. Think of the schematic as your layout map.

The Core Blocks of a CAN Node

  • CAN controller (U2, MCP2515): handles the CAN protocol and talks to the host over SPI. It generates the TXCAN and RXCAN logic signals.
  • CAN transceiver (U1, TJA1050): converts logic levels to differential CANH/CANL bus levels.
  • Termination: one 120 Ω resistor (R2) across the pair, switched in by a jumper (H1), at bus end nodes.
  • Bus connectors (H2, H3): two 2-pin CANH/CANL connectors wired in parallel, so the bus can enter and leave the node.
  • Supporting parts: an 8 MHz crystal with load capacitors, decoupling capacitors, and a reset pull-up resistor. Keep them away from the bus pair.
  • Optional protection: TVS/ESD diodes and a common-mode choke are not fitted in this reference node. Add them for noisy environments.

Noise hits CANH and CANL equally, and the receiver only reads the difference between them, so the noise cancels out. Your layout must keep the two wires twins. Any mismatch in length, spacing, or loading turns harmless noise into real errors.

What the Schematic Tells You About Layout

Schematic ElementLayout Action
Bus connectors H2 and H3 (in parallel)Place at the board edge, with the transceiver in the same corner
Termination resistor R2 and jumper H1Place on the bus path right after the connectors, and fit the jumper only at the physical end nodes of the bus
Decoupling caps (add one at each IC's power pins)Place at the power pins, with short ground vias
Crystal and load capacitorsKeep close to the CAN controller and away from CANH/CANL
TXCAN/RXCAN linesRoute as single-ended logic lines between controller and transceiver. They can take the long run

Read the schematic from the bus connectors inward and the placement order largely writes itself: connectors, termination, transceiver, CAN controller. The next section turns that reading into a fixed sequence.

Component Placement and Signal Flow of CAN Bus PCB

Placement, not routing, is the first and cheapest decision in a CAN layout. Three simple rules guide it: terminate at the entry, keep the bus path short, and keep noisy parts away from the pair. Together they follow the real path a signal takes through this node: bus connectors, termination, transceiver, CAN controller. The diagram below shows the order.

Figure 2. CAN node placement order from the board edge inward: bus connectors, termination (R2 with jumper H1), transceiver U1, CAN controller U2. The CANH/CANL pair stays short and direct, while TXCAN/RXCAN take the long run.

Figure 2. CAN node placement order from the board edge inward: bus connectors, termination (R2 with jumper H1), transceiver U1, CAN controller U2. The CANH/CANL pair stays short and direct, while TXCAN/RXCAN take the long run.

Terminate at the Entry: the 120 Ω Resistor and Jumper

Place the 120 Ω resistor close to the bus connectors, on the bus path between the connectors and the transceiver, so the cable sees 120 Ω as soon as it enters the board. It belongs only at the physical end nodes of the bus, so wire it through a jumper that either connects it across CANH and CANL or leaves it out. Values and schemes are covered in the termination section below.

Optional Protection: TVS/ESD Diodes and Common-Mode Choke

This reference node does not include TVS/ESD diodes or a common-mode choke, which keeps the example simple. For vehicles, long cables, or other noisy installations, reserve footprints for them so you can fit them without a re-spin. Place the TVS/ESD diodes as close to the connector as you can, so surge and ESD energy is shunted to ground before it reaches anything inside the board. TI engineers give the same advice on their E2E support forum (TI E2E thread). Keep the unprotected trace between the connector pad and the TVS as short as possible, and give the TVS a short, wide return through a via straight into the ground plane. A long ground path adds inductance, and that inductance raises the voltage the transceiver actually sees during a strike. Choose a TVS with low junction capacitance, since extra capacitance loads the bus and rounds the edges, which matters most at CAN FD data rates.

A common-mode choke, if fitted, sits immediately before the transceiver pins and after the termination. It is the last filtering stage that noise passes before reaching the chip, and it blocks common-mode EMI in both directions: noise coming in from the bus and noise leaving the node. Keep the CANH and CANL path lengths equal through the choke footprint, or the choke's symmetry is wasted.

Keep the Transceiver Close to the Connector

Minimize the trace distance between the transceiver pins and the connector. Any branch off the main bus path is a stub, and stubs cause impedance discontinuities and reflections. On the board, every stub must be as short as physically possible.

That is also why you should never route CANH and CANL across the whole board to reach a remotely placed connector. A long run behaves like an unterminated branch of the bus. Put the bus connectors and transceiver in the same corner of the board and let the controller signals (TXCAN, RXCAN) take the long trip instead, because those are single-ended logic signals that tolerate it. The two parallel connectors let the bus pass through the node without a stub.

Differential Pair Routing and CAN Bus Layout Impedance

Figure 3. Differential pair routing close-up showing CANH/CANL as a tightly coupled pair, with callouts for trace width (W), spacing (S), intra-pair length matching, consistent spacing along the route, solid ground plane underneath, and at least 3W clearance from neighboring signals.

Figure 3. Differential pair routing close-up showing CANH/CANL as a tightly coupled pair, with callouts for trace width (W), spacing (S), intra-pair length matching, consistent spacing along the route, solid ground plane underneath, and at least 3W clearance from neighboring signals.

CAN is a differential bus with a set impedance. So route CANH and CANL as one controlled-impedance pair, not as two ordinary digital traces.

In EasyEDA, create the pair before routing. Open Design, then Differential Pair Manager (Figure 3a), add a pair, and set CANH as the positive net and CANL as the negative net (Figure 3b). The router then keeps the two traces together at the width and gap set in the pair's design rule.

Figure 3a. Opening the Differential Pair Manager from the Design menu in EasyEDA.

Figure 3a. Opening the Differential Pair Manager from the Design menu in EasyEDA.

Figure 3b. Differential Pair Manager with CANH as the positive net and CANL as the negative net.

Figure 3b. Differential Pair Manager with CANH as the positive net and CANL as the negative net.

Targeting 120 Ω Differential Impedance

ISO 11898-2 defines a 120 Ω bus, and TI's CAN transceiver documentation builds its termination guidance around that figure (TI application note SLLA270). Design the PCB pair around a 120 Ω differential target so it matches the cable and the terminations, which minimizes reflections where the board meets the harness. This is the core of CAN bus layout impedance: the board should look like more of the same transmission line, not a bump in it.

Tolerance depends on speed. Classic CAN is fairly forgiving, but CAN FD is sensitive to impedance mismatch and reflections, so hold the pair within ±10% of 120 Ω, and tighter if your data rate demands it. Matching matters more as edge rates rise, which is why a layout that is acceptable at classic CAN 1 Mbps can fail at CAN FD multi-Mbps data-phase rates.

Impedance is set by the stackup, specifically dielectric thickness and dielectric constant (Er), not by hope. Use an impedance calculator, such as the JLCPCB impedance calculator, to derive the geometry from your real stackup rather than guessing from a rule of thumb.

CAN Bus Trace Width and Spacing

Figure 4. JLCPCB impedance calculator result for a 120 ohm edge-coupled differential pair (non coplanar) on the 4-layer JLC04161H-3313A stackup: trace width 5.2 mil, spacing 8 mil, referenced to the L2 ground plane.

Figure 4. JLCPCB impedance calculator result for a 120 Ω edge-coupled differential pair (non coplanar) on the 4-layer JLC04161H-3313A stackup: trace width 5.2 mil, spacing 8 mil, referenced to the L2 ground plane.

There is no universal CAN bus trace width. Width and spacing are solved together, from the stackup, to hit 120 Ω differential. The calculator result above gives 120 Ω differential on the 4-layer JLC04161H-3313A stackup, with a 5.2 mil (0.132 mm) trace width and 8 mil (0.203 mm) spacing, referenced to the L2 ground plane. It is valid only for that stackup, so treat it as a worked example of the method, not a number to copy.

Matching EasyEDA to the Calculator Result

A calculator result only helps if the board uses the same stackup and the same geometry. In EasyEDA, open Layer Manager, go to the Physical Stacking tab, and set the dielectric thicknesses to the values of the stackup you used in the calculator (Figure 4a). Then create a differential pair rule with the calculated trace width and spacing on the top layer (Figure 4b), set it as the default differential pair rule, and route the CANH/CANL pair with it. The router then holds the width and gap along the whole route.

Figure 4a. EasyEDA Layer Manager, Physical Stacking tab, edited to match the JLC04161H-3313A stackup used in the calculator: 0.2064 mm prepreg on each side of a 1.065 mm core, 1.5782 mm in total.

Figure 4a. EasyEDA Layer Manager, Physical Stacking tab, edited to match the JLC04161H-3313A stackup used in the calculator: 0.2064 mm prepreg on each side of a 1.065 mm core, 1.5782 mm in total.

Figure 4b. EasyEDA differential pair rule can_120 for the top layer: trace width 0.132 mm (minimum 0.119 mm, maximum 0.145 mm), spacing 0.203 mm, and a 0.127 mm pair length tolerance.

Figure 4b. EasyEDA differential pair rule can_120 for the top layer: trace width 0.132 mm (minimum 0.119 mm, maximum 0.145 mm), spacing 0.203 mm, and a 0.127 mm pair length tolerance.

The values used in this example are summarized below.

ParameterValue in this example
StackupJLC04161H-3313A, 4 layers, 1.6 mm board
Pair layer and referenceTop layer, referenced to the L2 ground plane
Target differential impedance120 Ω
Trace width (W)5.2 mil (0.132 mm)
Spacing (S)8 mil (0.203 mm)
Length tolerance within the pair0.127 mm (5 mil)
Clearance to other signalsAt least 3W, about 0.4 mm

One general rule is useful. Reaching 120 Ω, which is higher than the common 90 Ω and 100 Ω pairs, typically calls for thinner traces, larger spacing, or both.

Once the geometry is set, keep the spacing constant along the whole route so the coupling stays consistent. Avoid layer changes where possible. If one is unavoidable, place a ground via next to each signal via to give the return current a path. For short classic CAN runs the bus is forgiving, but building the 120 Ω habit now future-proofs the design for CAN FD.

Length Matching, Topology, and Stub Control

  • Route CANH and CANL as a tightly coupled pair with equal trace lengths. The intra-pair budget should be tighter for CAN FD.
  • Use a daisy-chain topology on the board. The bus path passes through, and the node taps off with the shortest possible stub.
  • Never route the pair as a star or with long branches.
  • Keep at least 3W spacing between the pair and other signals, and stay away from noisy switching nets.

For anchors, ISO 11898 and TI's transceiver datasheets cite a maximum stub of about 0.3 m for classic CAN at 1 Mbps (TI datasheet). TI's application note adds a rule of thumb that a stub should not exceed one-third of the line's critical length (SLLA270). CAN FD data-phase rates are higher, so the same logic demands shorter stubs. TI engineers say 2 Mbps can shorten the allowable stub but do not give a fixed figure, and the right limit depends on topology, so do not reuse the 0.3 m number (TI E2E). On the PCB itself, the stub should be effectively zero.

Termination Design on the PCB

Figure 5. Two termination schemes at a bus end node: (a) a single 120 ohm resistor across CANH/CANL, and (b) split termination with two 60 ohm resistors and their midpoint bypassed to GND through a 4.7 nF capacitor, with the common-mode filtering benefit annotated.

Figure 5. Two termination schemes at a bus end node: (a) a single 120 Ω resistor across CANH/CANL, and (b) split termination with two 60 Ω resistors and their midpoint bypassed to GND through a 4.7 nF capacitor, with the common-mode filtering benefit annotated.

Termination soaks up signal energy at the bus ends, like a soft wall that stops echoes. Right value, right style, and right position are what make the 120 Ω system work.

Standard 120 Ω and Split Termination

Standard termination is a single 120 Ω resistor across CANH and CANL at each physical end of the bus, ideally 1% tolerance. This node uses that scheme: R2 is 120 Ω, and jumper H1 connects it across the pair. With the jumper fitted the board is an end node, and with it removed the board is a mid-bus node. In any CAN bus PCB layout, only the two physical end nodes get terminated. Mid-bus nodes must not, because the extra loading kills the bus. A common alternative is split termination, which uses two 60 Ω resistors with the midpoint decoupled to ground through about 4.7 nF. It also filters common-mode noise and, per TI, improves emissions by reducing common-mode voltage fluctuations (TI datasheet). Read the math carefully, because it is easy to misread. The two 60 Ω resistors are in series, so the bus sees 120 Ω differential at all frequencies. It is not a 60 Ω termination. The midpoint capacitor blocks DC and gives only high-frequency common-mode noise a low-impedance path to ground, so neither the recessive bus level (about 2.5 V) nor the differential signal is affected.

Physical Placement of the Resistor and Jumper

Place termination resistor R2 and its jumper H1 on the bus path close to the bus connectors, so the cable sees the termination as it enters the board. That puts the resistor on the bus path itself, not on a stub that dangles off it.

Keep the CANH and CANL path lengths through the termination footprint symmetric. If a part has to sit on the bottom side, use short, symmetric return vias. Label the jumper clearly on the silkscreen (for example, TERM), so installers fit it only on the end nodes. One real-world tip: because the board may be either an end device or a mid-bus device, the jumper lets the same board work in both roles.

Grounding and EMC in CAN Bus Design

Figure 6. Before and after comparison: (left) CAN pair routed over a split in the ground plane with the return path detouring, creating a large loop and EMI risk; (right) the pair rerouted over a solid, unbroken ground plane with a tight return path directly beneath the traces.

Figure 6. Before and after comparison: (left) CAN pair routed over a split in the ground plane with the return path detouring, creating a large loop and EMI risk; (right) the pair rerouted over a solid, unbroken ground plane with a tight return path directly beneath the traces.

A differential pair still leans on the ground plane. The fastest way to ruin a good CAN layout is to break that plane. The next two sections cover the return path, the filtering, and what to avoid.

Keep an Unbroken Ground Plane Under the Pair

Even though CAN is differential, return current flows beneath the pair, and any split or gap under the route creates a loop antenna and an impedance bump. Never route CANH and CANL across plane splits or cutouts. Keep the transceiver's decoupling capacitors close to its power pins with short ground vias, and keep the crystal and its load capacitors next to the CAN controller, away from the pair. If you add TVS diodes, provide a solid plane under them so ESD current finds the lowest-impedance path to ground.

This guidance targets non-isolated CAN nodes, where the ground plane must stay unbroken. In isolated CAN designs, the bus-side and controller-side grounds do separate at the isolation barrier, but nothing may cross that gap except through the isolator itself, and CANH and CANL must never route over the isolation slot.

Common-Mode Noise Filtering Without Killing the Signal

The filtering toolkit in a CAN node is short, and this reference node does not use any of it on the bus. If EMC testing calls for it, start with a common-mode choke placed immediately before the transceiver pins and after the termination. Add optional small filter capacitors, roughly 40 pF to 100 pF from CANH and CANL to ground, for ESD and EMI. The tradeoff is honest: capacitance loads the bus and limits data rate, so it suits classic CAN better than CAN FD. In a TI E2E schematic review of a 5 Mbps CAN FD design, a TI engineer advised depopulating or reducing the 100 pF bus caps (TI E2E). One more caution: a choke can resonate with parasitic bus capacitance, so pick one rated for CAN data rates. For broader EMC coverage beyond CAN, see our guide to EMI shielding in PCB design.

CAN Bus PCB Layout Checklist

  • If TVS/ESD diodes are fitted, they sit within a few millimeters of the bus connectors.
  • If TVS diodes are fitted, their ground return is a short, wide via into the plane.
  • 120 Ω ±1% termination is enabled (jumper fitted) only at the two end nodes.
  • The placement order is bus connectors, termination, transceiver, CAN controller.
  • The pair is length-matched with constant spacing along the route.
  • Differential impedance is solved from the real stackup, within ±10% of 120 Ω.
  • No plane splits or cutouts sit under CANH/CANL.
  • On-board stubs are minimized to effectively zero.
  • At least 3W clearance is kept from other signals and noisy nets.
  • TXCAN goes to the transceiver TXD and RXCAN goes to RXD, with no crossed lines.
  • The crystal and its load capacitors sit close to the CAN controller, away from CANH/CANL.
JLCPCB $90 coupons for PCB layout orders — DFM-ready PCB files from schematics in as fast as 3 days

FAQs about CAN Bus PCB Layout

Q1. What differential impedance should a CAN bus PCB layout use?

Use 120 Ω differential, matching the ISO 11898-2 bus. Hold CAN bus layout impedance within about ±10% of that target, and tighter for CAN FD, where reflections hurt more.

Q2. What trace width should I use for CAN bus routing?

There is no universal CAN bus trace width. Width and spacing are solved together from your stackup to reach 120 Ω, as in the JLCPCB impedance-calculator example above (5.2 mil width and 8 mil spacing on the JLC04161H-3313A stackup). Reaching 120 Ω generally requires thinner traces and larger spacing than 90 Ω or 100 Ω pairs.

Q3. Where should the 120 Ω termination resistor be placed on the PCB?

Place it on the bus path close to the bus connectors, so the cable sees 120 Ω as it enters the board. Connect it through a jumper, and fit it only on the two physical end nodes of the bus.

Q4. How short should CAN bus stubs be on a PCB?

Classic CAN allows stubs of about 0.3 m at 1 Mbps. CAN FD needs shorter stubs, and TI does not publish a single fixed figure, so check your transceiver's documentation. On the board itself, stubs should be effectively zero.

Conclusion about CAN Bus PCB Layout

A reliable CAN bus is won in the layout. Signal-path placement, a 120 Ω controlled-impedance pair, correct termination, and an unbroken ground plane do more for robustness than any transceiver upgrade. Following these CAN bus PCB layout guidelines prevents the intermittent bus errors and EMC failures that are so costly to debug once the hardware is in the field.

Run the checklist before you release the board, and treat each failed item as a cheap fix now rather than an expensive re-spin later.

If you would rather focus on the circuit than the layout, upload your schematic to our professional PCB layout service and our engineers will handle the layout for you.

Keep Learning